Troponin T, cardiac - high-sensitive (biweekly-monthly sampling)

Meta Analysis

Matrix: Serum/plasma

Type median CV estimate lower CI limit higher CI limit Date Updated Tools
Between-subject
30.9
26.8
51.2
2022-05-23 21:49:39 UTC

References

No meta analysis Reference included in meta calculation Reference not included in meta calculation
Link Estimate of CVi Estimate of CVg Gender State of Well Being Matrix
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 8.3 26.8 Mixed Healthy (excl pregnant) Serum
Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods., Frankenstein L, Wu AH, Hallermayer K, Wians FH Jr, Giannitsis E, Katus HA., 2011, Clin Chem, 57(7), 1068-71 30.0 Mixed Healthy (excl pregnant) Plasma
Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods., Frankenstein L, Wu AH, Hallermayer K, Wians FH Jr, Giannitsis E, Katus HA., 2011, Clin Chem, 57(7), 1068-71 31.0 Mixed Healthy (excl pregnant) Plasma
Variability of biomarkers in patients with chronic heart failure and healthy controls, Meijers WC, Van del Velde AR, Kobold ACM, et al, 2017, Eur J Hearth Failure , 19, 357-65 16.0 51.2 Mixed Healthy (excl pregnant) Plasma
Circulating Cardiac Troponin T Exhibits a Diurnal Rhythm, Klinkenberg LJ, Van Dijk JW, Tan FES, Van Loon LJC, Van Dieijen-Visser MP and Meex SJR, 2014, J Am Col Cardiol, 63, 1788-95 9.7 43.8 Males Non-healthy (excl pregnant) Plasma
Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients: implications for clinical practice, Fahim MA, Hayen AD, Horvath AR, Dimeski G, Coburn A, Tan K, Johnson DW, Craig JC, Campbell SB and Hawley CM, 2015, Clin Chem Lab Med, 53, 715-22 12.6 79.0 Mixed Non-healthy (excl pregnant) Plasma
Biological variation of cardiac troponin in stable haemodialysis patients., Mbagaya W, Luvai A and Lopez B, 2015, Ann Clin Biochem, 52, 562-8 10.5 64.2 Mixed Non-healthy (excl pregnant) Plasma
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 1.2 32.6 Mixed Healthy (excl pregnant) Serum
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 1.9 110.0 Mixed Non-healthy (excl pregnant) Serum
Diagnosis of acute myocardial infarction in hemodialysis patients may be feasible by comparing variation of cardiac troponins during acutepresentation to baseline variation, Van Berkel M, Dekker MJE, Bogers H et al, 2016, Clin Chim Acta, 456, 36-41 12.0 68.0 Mixed Non-healthy (excl pregnant) Plasma
Circulating Cardiac Troponin T Exhibits a Diurnal Rhythm, Klinkenberg LJ, Van Dijk JW, Tan FES, Van Loon LJC, Van Dieijen-Visser MP and Meex SJR, 2014, J Am Col Cardiol, 63, 1788-95 12.7 40.4 Males Non-healthy (excl pregnant) Plasma
Biological and analytical variability of a novel high-sensivity cardiac troponin T assay, Vasile VC, Saenger AK, Kroning JM and Jaffe AS, 2010, Clin Chem, 56, 1086-90 48.2 85.9 Mixed Healthy (excl pregnant) Serum
Variability of biomarkers in patients with chronic heart failure and healthy controls, Meijers WC, Van del Velde AR, Kobold ACM, et al, 2017, Eur J Hearth Failure , 19, 357-65 11.1 96.6 Mixed Non-healthy (excl pregnant) Plasma
Sources of variability in measurements in cardiac Troponin T measured with high sensitivity assay in a community based sample: the ARIC Study, Agarwal SK, Avery CL, Ballantyne CM et al, 2011, Clin Chem, 57(6), 891-7 16.6 Mixed Healthy (excl pregnant) Plasma
Biological and analytical variability of a novel high-sensivity cardiac troponin T assay, Vasile VC, Saenger AK, Kroning JM and Jaffe AS, 2010, Clin Chem, 56, 1086-90 94.0 94.0 Mixed Healthy (excl pregnant) Serum
Circadian rhythm of blood cardíac troponin T concentration, Fournier S, Iten L, Marques-Vidal P, Boulat O et al, 2017, Clin Res Cardiol, , 9.67 47.24 Mixed Healthy (excl pregnant) Plasma
Monthly reference change value of cardiac troponin in hemodialysis patients as a useful tool for long-term cardiovascular management. , Badiou S, Boudet A, Leray-Moragues H et al, 2016, Clin Biochem, , 7.2 50.7 Mixed Non-healthy (excl pregnant) Plasma
Short- and Long-term Individual Variation in Cardiac Troponin in Patients with Stable Coronary Artery Disease, Nordenskjöld AM, Ahlström H et al. , 2013, Clin Chem, 59(2), 401-9 7.0 70.0 Mixed Non-healthy (excl pregnant) Plasma
Variation of Cardiac Troponin I and T Measured with Sensitive Assays in Emergency Department Patients with Noncardiac Chest Pain, Scharnhorst V, Krasznai K et al. , 2012, Clin Chem, 58(8), 1208-14 11.0 Mixed Non-healthy (excl pregnant) Plasma
Diagnosis of acute myocardial infarction in hemodialysis patients may be feasible by comparing variation of cardiac troponins during acutepresentation to baseline variation, Van Berkel M, Dekker MJE, Bogers H et al, 2016, Clin Chim Acta, 456, 36-41 10.0 66.0 Mixed Non-healthy (excl pregnant) Plasma
Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods., Frankenstein L, Wu AH, Hallermayer K, Wians FH Jr, Giannitsis E, Katus HA., 2011, Clin Chem, 57(7), 1068-71 15.0 Mixed Healthy (excl pregnant) Plasma
The variation in high sensitive cardíac troponin concentration during haemodialysis treatment is not similar to the biological variation observed in stable end stage renal disease patients, Skadberg Ø, Sandberg S, Røraas T, Petersen PH, Sellevoll H, Svarstad E, Sæle K and Aakre KM, 2016, Scand J Clin Lab Invest, 76, 645-52 8.0 101.9 Mixed Non-healthy (excl pregnant) Serum
Long-term biological variation of high-sensitivity cardiac troponin T using minimal important differences and reference change values in stable outpatients with cardiovascular disease. Clin Biochem 2019, Täger T, Giannitsis E, Greve K et al, 2019, Clin Biochem, , 15.9 Mixed Non-healthy (excl pregnant) Plasma
Biological variation of cardiac troponins in chronic kidney disease., Jones RA, Barratt J, Brettell EA, Cockwell P, Dalton RN, Deeks JJ, Eaglestone G, Pellatt-Higgins T, Kalra PA, Khunti K, Morris FS, Ottridge RS, Sitch AJ, Stevens PE, Sharpe CC, Sutton AJ, Taal MW, Lamb EJ, 2020, Ann Clin Biochem, , 4563220906431 7.4 78.4 Mixed Non-healthy (excl pregnant) Plasma
The variation in high sensitive cardíac troponin concentration during haemodialysis treatment is not similar to the biological variation observed in stable end stage renal disease patients, Skadberg Ø, Sandberg S, Røraas T, Petersen PH, Sellevoll H, Svarstad E, Sæle K and Aakre KM, 2016, Scand J Clin Lab Invest, 76, 645-52 7.3 94.4 Mixed Non-healthy (excl pregnant) Serum
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 8.3 101.5 Mixed Non-healthy (excl pregnant) Serum
Circulating Cardiac Troponin T Exhibits a Diurnal Rhythm, Klinkenberg LJ, Van Dijk JW, Tan FES, Van Loon LJC, Van Dieijen-Visser MP and Meex SJR, 2014, J Am Col Cardiol, 63, 1788-95 14.2 38.4 Males Non-healthy (excl pregnant) Plasma
Short- and Long-term Individual Variation in Cardiac Troponin in Patients with Stable Coronary Artery Disease, Nordenskjöld AM, Ahlström H et al. , 2013, Clin Chem, 59(2), 401-9 11.0 65.0 Mixed Non-healthy (excl pregnant) Plasma
Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients: implications for clinical practice, Fahim MA, Hayen AD, Horvath AR, Dimeski G, Coburn A, Tan K, Johnson DW, Craig JC, Campbell SB and Hawley CM, 2015, Clin Chem Lab Med, 53, 715-22 7.9 83.0 Mixed Non-healthy (excl pregnant) Plasma
Sources of variability in measurements in cardiac Troponin T measured with high sensitivity assay in a community based sample: the ARIC Study, Agarwal SK, Avery CL, Ballantyne CM et al, 2011, Clin Chem, 57(6), 891-7 54.9 Mixed Healthy (excl pregnant) Plasma
Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods., Frankenstein L, Wu AH, Hallermayer K, Wians FH Jr, Giannitsis E, Katus HA., 2011, Clin Chem, 57(7), 1068-71 21.0 Mixed Healthy (excl pregnant) Plasma
Biological variation of cardiac markers in patients with aortic valve stenosis, Peeters F, Kietselaer B et al, 2019, Open Heart, , 11.2 57.2 Mixed Non-healthy (excl pregnant) Serum
© 2018 - 2020 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.

Email Us

European Federation of Clinical Chemistry and Laboratory Medicine
Via Carlo Farini 81
20159 Milano - Italy