Troponin I, cardiac - high-sensitive (biweekly-monthly sampling)

Meta Analysis

Matrix: Serum/plasma

Type median CV estimate lower CI limit higher CI limit Date Updated Tools
Within-subject
12.0
2.6
95.4
2022-05-23 21:49:40 UTC

References

No meta analysis Reference included in meta calculation Reference not included in meta calculation
Link Estimate of CVi Estimate of CVg Gender State of Well Being Matrix
Short- and longterm biological variation in cardiac Troponin I measured with a high sensitive assay: implications for clinical practice, Wu AHB, Lu QA, Todd J, Moecks J and Wlans F, 2009, Clin Chem, 55, 52-8 14.0 63.0 Mixed Healthy (excl pregnant) Plasma
Short- and Long-term Biologic Variability of Galectin-3 and Other Cardiac Biomarkers in Patients with Stable Heart Failure and Healthy Adults, Schindler EI, Szymanski JJ, Hock KG et al, 2016, Clin Chem, 62(2), 360-6 14.5 44.0 Mixed Healthy (excl pregnant) Plasma
Short and long-term biological variability of troponin I determined using the Architect Stat high sensitive troponin-I assay, Goldberg J, Iriarte B, Prostko J, Frias E, Ravalico T and Hebbar S, 2011, Clin Chem, 57 (10) suppl, C-04 80.4 Mixed Healthy (excl pregnant) Serum
The European Biological Variation Study (EuBIVAS): weekly biological variation of cardiac troponin I estimated by the use of two different high-sensitivity cardiac troponin I assays, Ceriotti F, Diaz-Garzon J et al, 2020, Clin Chem Lab Med, , 13.9 36.3 Mixed Healthy (excl pregnant) Serum
Short- and Long-term Biologic Variability of Galectin-3 and Other Cardiac Biomarkers in Patients with Stable Heart Failure and Healthy Adults, Schindler EI, Szymanski JJ, Hock KG et al, 2016, Clin Chem, 62(2), 360-6 14.7 56.7 Mixed Healthy (excl pregnant) Plasma
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 15.6 25.9 Mixed Healthy (excl pregnant) Serum
Short and long-term biological variability of troponin I determined using the Architect Stat high sensitive troponin-I assay, Goldberg J, Iriarte B, Prostko J, Frias E, Ravalico T and Hebbar S, 2011, Clin Chem, 57 (10) suppl, C-04 117.0 Mixed Healthy (excl pregnant) Plasma
Biologic Variation of a novel cardiac Troponin I assay, Vasile VC, Saenger AK, Kroning JM, Klee GG and Jaffe AS, 2011, Clin Chem, 57, 1080-1 2.6 41.6 Mixed Healthy (excl pregnant) Serum
Short and long-term biological variability of troponin I determined using the Architect Stat high sensitive troponin-I assay, Goldberg J, Iriarte B, Prostko J, Frias E, Ravalico T and Hebbar S, 2011, Clin Chem, 57 (10) suppl, C-04 24.4 124.0 Mixed Healthy (excl pregnant) Serum
Short and long-term biological variability of troponin I determined using the Architect Stat high sensitive troponin-I assay, Goldberg J, Iriarte B, Prostko J, Frias E, Ravalico T and Hebbar S, 2011, Clin Chem, 57 (10) suppl, C-04 37.1 179.2 Mixed Healthy (excl pregnant) Plasma
Long-term biological validation in cardiac troponin I, Wu AHB, Akhigbea P and Wians F, 2012, Clin Biochem, 45, 714-6 28.0 71.0 Mixed Non-healthy (excl pregnant) Plasma
Longitudinal Studies of Cardiac Troponin I in a Large Cohort of Healthy Children, Koerbin G, Potter JM et al. , 2012, Clin Chem, 58(12), 1665-72 33.0 106.0 Mixed Healthy (excl pregnant) Serum
Short- and longterm biological variation in cardiac Troponin I measured with a high sensitive assay: implications for clinical practice, Wu AHB, Lu QA, Todd J, Moecks J and Wlans F, 2009, Clin Chem, 55, 52-8 9.7 57.0 Mixed Healthy (excl pregnant) Plasma
Short- and Long-term Biologic Variability of Galectin-3 and Other Cardiac Biomarkers in Patients with Stable Heart Failure and Healthy Adults, Schindler EI, Szymanski JJ, Hock KG et al, 2016, Clin Chem, 62(2), 360-6 8.5 99.3 Mixed Non-healthy (excl pregnant) Plasma
Short- and Long-term Individual Variation in Cardiac Troponin in Patients with Stable Coronary Artery Disease, Nordenskjöld AM, Ahlström H et al. , 2013, Clin Chem, 59(2), 401-9 14.0 187.0 Mixed Non-healthy (excl pregnant) Plasma
Short- and Long-term Individual Variation in Cardiac Troponin in Patients with Stable Coronary Artery Disease, Nordenskjöld AM, Ahlström H et al. , 2013, Clin Chem, 59(2), 401-9 24.0 163.0 Mixed Non-healthy (excl pregnant) Plasma
The variation in high sensitive cardíac troponin concentration during haemodialysis treatment is not similar to the biological variation observed in stable end stage renal disease patients, Skadberg Ø, Sandberg S, Røraas T, Petersen PH, Sellevoll H, Svarstad E, Sæle K and Aakre KM, 2016, Scand J Clin Lab Invest, 76, 645-52 13.2 142.4 Mixed Non-healthy (excl pregnant) Serum
The variation in high sensitive cardíac troponin concentration during haemodialysis treatment is not similar to the biological variation observed in stable end stage renal disease patients, Skadberg Ø, Sandberg S, Røraas T, Petersen PH, Sellevoll H, Svarstad E, Sæle K and Aakre KM, 2016, Scand J Clin Lab Invest, 76, 645-52 14.8 150.5 Mixed Non-healthy (excl pregnant) Serum
Short-term biological variation and diurnal rhythm of cardiac troponin I (Access hs-TnI) in healthy subjects., Zaninotto M, Padoan A, Mion MM, Marinova M, Plebani M., 2020, Clin Chim Acta., 504, 163-167 4.2 23.44 Mixed Healthy (excl pregnant) Plasma
Biological variation of cardiac troponins in chronic kidney disease., Jones RA, Barratt J, Brettell EA, Cockwell P, Dalton RN, Deeks JJ, Eaglestone G, Pellatt-Higgins T, Kalra PA, Khunti K, Morris FS, Ottridge RS, Sitch AJ, Stevens PE, Sharpe CC, Sutton AJ, Taal MW, Lamb EJ, 2020, Ann Clin Biochem, , 4563220906431 15.0 105.6 Mixed Non-healthy (excl pregnant) Plasma
The European Biological Variation Study (EuBIVAS): weekly biological variation of cardiac troponin I estimated by the use of two different high-sensitivity cardiac troponin I assays, Ceriotti F, Diaz-Garzon J et al, 2020, Clin Chem Lab Med, , 16.6 40.3 Mixed Healthy (excl pregnant) Serum
Monthly reference change value of cardiac troponin in hemodialysis patients as a useful tool for long-term cardiovascular management. , Badiou S, Boudet A, Leray-Moragues H et al, 2016, Clin Biochem, , 18.6 79.2 Mixed Non-healthy (excl pregnant) Plasma
Biological variation of cardiac markers in patients with aortic valve stenosis, Peeters F, Kietselaer B et al, 2019, Open Heart, , 9.2 35.0 Mixed Non-healthy (excl pregnant) Serum
Biologic Variation of a novel cardiac Troponin I assay, Vasile VC, Saenger AK, Kroning JM, Klee GG and Jaffe AS, 2011, Clin Chem, 57, 1080-1 3.4 25.3 Mixed Healthy (excl pregnant) Serum
Short- and Long-term Biologic Variability of Galectin-3 and Other Cardiac Biomarkers in Patients with Stable Heart Failure and Healthy Adults, Schindler EI, Szymanski JJ, Hock KG et al, 2016, Clin Chem, 62(2), 360-6 9.6 100.1 Mixed Non-healthy (excl pregnant) Plasma
Use of observed within-person variation of cardíac troponin in emergency department patients for determination of biological variation and percentage and absolute reference change values, Simpson AJ, Potter JM, Koerbin G, Oakman C, Cullen L, Wilkes GJ, Scanlan SL, Parsonage W and Hickman PE. , 2014, Clin Chem, 60, 848-54 14.0 84.0 Mixed Healthy (excl pregnant) Plasma
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 3.3 148.1 Mixed Non-healthy (excl pregnant) Serum
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 5.0 37.7 Mixed Healthy (excl pregnant) Serum
Weekly and 90-Minute Biological Variations in Cardiac Troponin T and Cardiac Troponin I in Hemodialysis Patients and Healthy Controls, Aakre KM, Roraas T et al, 2014, Clin Chem, 60(6), 838-47 14.3 126.7 Mixed Non-healthy (excl pregnant) Serum
Short-term biological variation of cardiac troponin I measured with three high-sensitive assays, Apple FS, Murakami MM, Wians FH, Ler R, Kaczmarek JM and Wu AHB, 2011, Clin Chem, 57, C-05 15.2 70.5 Mixed Healthy (excl pregnant) Serum
Short-term biological variation of cardiac troponin I measured with three high-sensitive assays, Apple FS, Murakami MM, Wians FH, Ler R, Kaczmarek JM and Wu AHB, 2011, Clin Chem, 57, C-05 6.1 34.8 Mixed Healthy (excl pregnant) Serum
© 2018 - 2020 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.

Email Us

European Federation of Clinical Chemistry and Laboratory Medicine
Via Carlo Farini 81
20159 Milano - Italy