Parathyroid hormone

Reference

Reference
Lutsey P, Parrinello CM, Misialek JR et al, 2016, Clin Chem, 12, 1647-53 , Short-term variability of vitamin D-related biomarkers

Scoring

Total Score

C5,7,8,10,11,13

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand A
5. Pre-Analytical C
6. Replicate Analysis B
7. Steady State C
8. Outlier Analysis C
9. Normality B
10. Variance Homogeneity C
11. ANOVA C
12. CI A
13. No of Results C
14. Concentrations A
15. Total Score C5,7,8,10,11,13
Comment

Item Details

Parameter Score
Matrix Serum
Measurand Parathyroid hormone
Unit pg / mL
Overall Analytical Principle Method Immunoassay; Non-competitive
Number of Subjects 160
Number of Subjects included in BV estimation 160
Ethinicity Mixed
Age Mean / Median 76.0
Age Min 68.0
Age Max 88.0
Age SD
Number of Males 64
Number of Females 96
State of Well Being Non-healthy (excl pregnant)
Study Duration Length 6
Study Duration Units Week
Sampling Intervals, e.g. X sample(s) per Interval Unit 1
Interval Units Other
Sampling Times Start Time:
End Time:
Number of Samples 2
Average Number of Samples Used for BV Estimation 2.0
Average Number of Replicates
Estimates of CVi 16.7
Calculated Confidence Intervals of CVi Lower: 14.84, Upper: 18.93
Estimates of CVg 37.9
Calculated Confidence Intervals of CVg Lower: 33.71, Upper: 43.03
Analytical CV 5.1
Calculated Confidence Intervals of Analytical CV Lower: 4.10, Upper: 6.75
Measurand Mean 45.7
Measurand Min
Measurand Max
Measurand SD 18.5

Coding

© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.