Luteinising hormone (LH)

Reference

Reference
Ricós C and Arbós MA, 1990, Ann Clin Biochem, 27, 353-8 , Quality goals for hormone testing

Scoring

Total Score

C4,8,10

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand C
5. Pre-Analytical A
6. Replicate Analysis B
7. Steady State B
8. Outlier Analysis C
9. Normality B
10. Variance Homogeneity C
11. ANOVA B
12. CI A
13. No of Results A
14. Concentrations B
15. Total Score C4,8,10
Comment

Item Details

Parameter Score
Matrix Serum
Measurand Luteinising hormone (LH)
Unit _ / _
Overall Analytical Principle Method Immunoassay; ELISA
Number of Subjects 9
Number of Subjects included in BV estimation 9
Ethinicity Caucasian
Age Mean / Median
Age Min 25.0
Age Max 40.0
Age SD
Number of Males
Number of Females 9
State of Well Being
Healthy (excl pregnant)
Diseases
Study Duration Length 1
Study Duration Units Week
Sampling Intervals, e.g. X sample(s) per Interval Unit 1
Interval Units Day
Sampling Times Start Time:
End Time:
Number of Samples 7
Average Number of Samples Used for BV Estimation 7.0
Average Number of Replicates 2.0
Estimates of CVi 14.5
Calculated Confidence Intervals of CVi Lower: 11.94, Upper: 18.15
Estimates of CVg 27.8
Calculated Confidence Intervals of CVg Lower: 18.64, Upper: 51.50
Analytical CV 6.3
Calculated Confidence Intervals of Analytical CV Lower: 5.37, Upper: 7.63
Measurand Mean
Measurand Min
Measurand Max
Measurand SD

Coding