Sexual-hormone-binding-globulin (SHBG)

Reference

Reference
Collier CP, Morales A, Clark A, Lam M, Wynne-Edwards K and Black A, 2010, J Urol, 183, 2294-9 , The significance of biological variation in the diagnosis of testosterone deficiency, and consideration of the relevance of total, free and bioavailable testosterone determinations

Scoring

Total Score

C3,8,10,11,12

Parameter Score
1. Scale A
2. Study Population A
3. Samples C
4. Measurand A
5. Pre-Analytical A
6. Replicate Analysis A
7. Steady State A
8. Outlier Analysis C
9. Normality B
10. Variance Homogeneity C
11. ANOVA C
12. CI C
13. No of Results A
14. Concentrations A
15. Total Score C3,8,10,11,12
Comment

Item Details

Parameter Score
Matrix Unknown
Measurand Sexual-hormone-binding-globulin (SHBG)
Unit ng / dL
Overall Analytical Principle Method Immunoassay; Competitive
Number of Subjects 87
Number of Subjects included in BV estimation 87
Ethinicity Caucasian
Age Mean / Median
Age Min 50.0
Age Max 80.0
Age SD
Number of Males 87
Number of Females
State of Well Being Healthy (excl pregnant)
Study Duration Length 1
Study Duration Units Day
Sampling Intervals, e.g. X sample(s) per Interval Unit 2
Interval Units Hour
Sampling Times Start Time: 7
End Time: 10
Number of Samples 2
Average Number of Samples Used for BV Estimation 2.0
Average Number of Replicates 1.0
Estimates of CVi 11.3
Calculated Confidence Intervals of CVi Lower: 9.47, Upper: 13.50
Estimates of CVg 33.7
Calculated Confidence Intervals of CVg Lower: 0.00, Upper: 39.92
Analytical CV 4.0
Calculated Confidence Intervals of Analytical CV Lower: 3.00, Upper: 6.00
Measurand Mean
Measurand Min
Measurand Max
Measurand SD

Coding

© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.
European Federation of Clinical Chemistry and Laboratory Medicine
Ms Silvia Cattaneo
Via Carlo Farini 81
20159 Milano - Italy