Cholesterol

Included in meta analysis

Reference

Reference
Hölzel WGE, 1987, Clin Chem, 33, 57-61 , Intra-individual variation of some analytes in serum of patients with insulin-dependent diabetes mellitus

Scoring

Total Score

C8,13

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand A
5. Pre-Analytical A
6. Replicate Analysis A
7. Steady State A
8. Outlier Analysis C
9. Normality A
10. Variance Homogeneity A
11. ANOVA B
12. CI A
13. No of Results C
14. Concentrations A
15. Total Score C8,13
Comment

Item Details

Parameter Score
Matrix Serum
Measurand Cholesterol
Unit mmol / L
Overall Analytical Principle Method Spectrophotometry; UV/VISIBLE
Number of Subjects 14
Number of Subjects included in BV estimation 14
Ethinicity Caucasian
Age Mean / Median 33.5
Age Min
Age Max
Age SD
Number of Males
Number of Females 14
State of Well Being Healthy (excl pregnant)
Study Duration Length 8
Study Duration Units Week
Sampling Intervals, e.g. X sample(s) per Interval Unit 1
Interval Units Week
Sampling Times Start Time:
End Time:
Number of Samples 8
Average Number of Samples Used for BV Estimation 8.0
Average Number of Replicates 2.0
Estimates of CVi 4.37
Calculated Confidence Intervals of CVi Lower: 3.79, Upper: 5.13
Estimates of CVg
Calculated Confidence Intervals of CVg Lower: 0.00, Upper:
Analytical CV 1.68
Calculated Confidence Intervals of Analytical CV Lower: 1.49, Upper: 1.93
Measurand Mean 4.55
Measurand Min
Measurand Max
Measurand SD

Coding

© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.