Creatinine

Reference

Reference
Fraser CG., Cummings ST., Wilkinson SP., Neville RG., Knox JDE, Ho O and MacWalter RS, 1989, Clin Chem, 35, 783-6 , Biological variability of 26 clinical chemistry analytes in elderly people

Originally from this reference: Clin Chem, Fraser CG., Cummings ST., Wilkinson SP., Neville RG., Knox JDE, Ho O and MacWalter RS, 1989


ID: 0049

Scoring

Total Score

C4,10

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand C
5. Pre-Analytical A
6. Replicate Analysis A
7. Steady State A
8. Outlier Analysis B
9. Normality B
10. Variance Homogeneity C
11. ANOVA A
12. CI A
13. No of Results A
14. Concentrations A
15. Total Score C4,10
Comment

Item Details

Parameter Score
Matrix Serum
Measurand Creatinine
Unit micromol / L
Overall Analytical Principle Method Unknown
Number of Subjects 27
Number of Subjects included in BV estimation 27
Ethinicity Unknown
Age Mean / Median
Age Min 70.0
Age Max 83.0
Age SD
Number of Males 14
Number of Females 13
State of Well Being Healthy (excl pregnant)
Study Duration Length 140
Study Duration Units Day
Sampling Intervals, e.g. X sample(s) per Interval Unit 2
Interval Units Month
Sampling Times Start Time: 07:00
End Time: 09:00
Number of Samples 10
Average Number of Samples Used for BV Estimation 10.0
Average Number of Replicates 2.0
Estimates of CVi 4.3
Calculated Confidence Intervals of CVi Lower: 3.86, Upper: 4.81
Estimates of CVg 18.3
Calculated Confidence Intervals of CVg Lower: 14.44, Upper: 24.95
Analytical CV 2.8
Calculated Confidence Intervals of Analytical CV Lower: 2.58, Upper: 3.06
Measurand Mean 93.8
Measurand Min
Measurand Max
Measurand SD

Coding

Parameter Score
Healthy Population true
Adult Population false
Weekly Samplings true
Reviewed true
Published true
Gender for Meta-Analysis Mixed
Snomed CT
NPU
LOINC
Comment
© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.