HDL cholesterol

Included in meta analysis

Reference

Reference
Ford RP, 1989, Ann Clin Biochem, 26, 281-5 , Essential data derived from biological variation for establishment and use of lipid analyses

Scoring

Total Score

C8,10,13

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand A
5. Pre-Analytical A
6. Replicate Analysis A
7. Steady State B
8. Outlier Analysis C
9. Normality B
10. Variance Homogeneity C
11. ANOVA A
12. CI A
13. No of Results C
14. Concentrations A
15. Total Score C8,10,13
Comment

Item Details

Parameter Score
Matrix Serum
Measurand HDL cholesterol
Unit mmol / L
Overall Analytical Principle Method Spectrophotometry; UV/VISIBLE
Number of Subjects 12
Number of Subjects included in BV estimation
Ethinicity Caucasian
Age Mean / Median
Age Min 23.0
Age Max 48.0
Age SD
Number of Males 6
Number of Females 6
State of Well Being Healthy (excl pregnant)
Study Duration Length 4
Study Duration Units Month
Sampling Intervals, e.g. X sample(s) per Interval Unit 1
Interval Units Week
Sampling Times Start Time:
End Time:
Number of Samples 10
Average Number of Samples Used for BV Estimation 10.0
Average Number of Replicates 2.0
Estimates of CVi 5.5
Calculated Confidence Intervals of CVi Lower: 4.78, Upper: 6.43
Estimates of CVg 27.2
Calculated Confidence Intervals of CVg Lower: 19.46, Upper: 44.96
Analytical CV 2.5
Calculated Confidence Intervals of Analytical CV Lower: 2.22, Upper: 2.86
Measurand Mean 1.37
Measurand Min
Measurand Max
Measurand SD

Coding

© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.
European Federation of Clinical Chemistry and Laboratory Medicine
Ms Silvia Cattaneo
Via Carlo Farini 81
20159 Milano - Italy
biologicalvariationdatabase@eflm.eu