Thyroglobulin

Reference

Reference
Jensen E, Petersen PH, Blaabjerg O and Hegedüs L, 2007, Clin Chem Lab Med, 45, 1058-64 , Biological variation of thyroid autoantibodies and thyroglobulin

Originally from this reference: Clin Chem Lab Med, Jensen E, Petersen PH, Blaabjerg O and Hegedüs L, 2007


ID: 0207

Scoring

Total Score

B8,13

Parameter Score
1. Scale A
2. Study Population A
3. Samples A
4. Measurand A
5. Pre-Analytical A
6. Replicate Analysis A
7. Steady State A
8. Outlier Analysis B
9. Normality A
10. Variance Homogeneity A
11. ANOVA A
12. CI A
13. No of Results B
14. Concentrations A
15. Total Score B8,13
Comment

Item Details

Parameter Score
Matrix Serum
Measurand Thyroglobulin
Unit ug / L
Overall Analytical Principle Method Fluoroimmunometry
Number of Subjects 24
Number of Subjects included in BV estimation 21
Ethinicity Caucasian
Age Mean / Median 35.5
Age Min 23.0
Age Max 46.0
Age SD
Number of Males
Number of Females 24
State of Well Being Healthy (excl pregnant)
Study Duration Length 36
Study Duration Units Day
Sampling Intervals, e.g. X sample(s) per Interval Unit 2
Interval Units Week
Sampling Times Start Time: 07:30
End Time: 11:00
Number of Samples 9
Average Number of Samples Used for BV Estimation 9.0
Average Number of Replicates 2.0
Estimates of CVi 16.2
Calculated Confidence Intervals of CVi Lower: 14.61, Upper: 18.17
Estimates of CVg 128.0
Calculated Confidence Intervals of CVg Lower: 0.00, Upper: 183.00
Analytical CV 2.9
Calculated Confidence Intervals of Analytical CV Lower: 2.63, Upper: 3.23
Measurand Mean 5.1
Measurand Min 0.0
Measurand Max 16.3
Measurand SD

Coding

Parameter Score
Healthy Population true
Adult Population true
Weekly Samplings true
Reviewed false
Published false
Gender for Meta-Analysis Females
Snomed CT
NPU
LOINC
Comment NB high CVg
© 2018 - 2019 This website and its content is copyright of EFLM. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the website as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system.